MC 6012 Load Cells
|
|
|
|
|
|
| |
|
|
|
Measure
Side and Radial Loads in Tire Testing Applications!
|
 |
|
The MC
6012 Series load cells are designed to measure the side and radial
loads developed in tire testing applications. Two load cells are normally
used in typical applications as shown in the figure below. Overload
protection up to 200% of capacity is provided for all axes.
You can download a complete
brochure about MC 6012 Load Cells in PDF format by clicking
here.
|
  |
SPECIFICATIONS
|
Output
at Rated Capacity
|
1.00
mV/V nominal |
|
Overload
Capacity
|
200%
of Full Scale (FS) |
|
Non-linearity
|
±0.25%
FS |
|
Hysteresis
|
±0.25%
FS |
|
Repeatability
|
±0.05%
FS |
|
Excitation
Voltage
|
±15
vdc, maximum |
|
Bridge
Resistance
|
350
Ohms, nominal |
|
Compensated
Temperature Range
|
70 to 150
°F |
|
Temperature
Effect on Zero
|
±0.002%
FS / °F |
|
Temperature
Effect on Span
|
±0.002%
of Reading / °F |
|
Zero
Offset
|
0.000 ±0.020
mV/V |
|
Shunt
Cal
|
1.000 mV/V
w/87.150K Ohm resistor |
|
|
PART
NO.
|
CAPACITIES
|
|
066012-01105
|
1,000 lbf,
500 lbf
|
|
066012-00102
|
1,000 lbf,
250 lbf
|
|
Working
hard to meet RoHS requirements for a safer, cleaner
environment!
Copyright
2007 RS Technologies Ltd., Farmington Hills, MI 48335 USA | Bookmark this